RdF Corporation
AN-TBL // Platinum RTD & TC
_ _
_ _
overview
product catalog
application notes
_
company info
news & updates
contact us
_
 

Thermocouple values in light gray are outside tolerenced limits__
ASTM E-230

* Indicates maximum temperature for MgO insulated TC diameter 1/8
ASTM E-608

** Indicates maximum temperature for MgO insulated TC diameter 1/4
ASTM E-608

_
Celsius: 1 | 2 | 3     Farenheit: 1 | 2 | 3 | 4 | 5 | 6 | 7   
RdF Platinum RTD & Thermocouple Tables 7.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
°F 100 Ω RTD _ 100 Ω RTD _ T/C _ T/C _ T/C _ T/C _
IEC 751 _ RdF Reference _ Type K _ Type J _ Type T _ Type E _
a=0.00385055 _ a=0.003924008 _ Cr/Al _ Ir/Con _ Cu/Con _ Cr/Con _
resistance, Ω _ resistance, Ω _ millivolts _ millivolts _ millivolts _ millivolts _
_ _ _ _ _ _ _ _ _ _ _ _ _ _
2310   ----   ----   51.198   ----   ----   ----  
2320   ----   ----   51.395   ----   ----   ----  
2330   ----   ----   51.591   ----   ----   ----  
2340   ----   ----   51.787   ----   ----   ----  
2350   ----   ----   51.982   ----   ----   ----  
2360   ----   ----   52.177   ----   ----   ----  
2370   ----   ----   52.371   ----   ----   ----  
2380   ----   ----   52.565   ----   ----   ----  
2390   ----   ----   52.759   ----   ----   ----  
2400   ----   ----   52.952   ----   ----   ----  
2410   ----   ----   53.144   ----   ----   ----  
2420   ----   ----   53.336   ----   ----   ----  
2430   ----   ----   53.528   ----   ----   ----  
2440   ----   ----   53.719   ----   ----   ----  
2450   ----   ----   53.910   ----   ----   ----  
2460   ----   ----   54.100   ----   ----   ----  
2470   ----   ----   54.289   ----   ----   ----  
2480   ----   ----   54.479   ----   ----   ----  
2490   ----   ----   54.668   ----   ----   ----  
2500   ----   ----   54.856   ----   ----   ----  
                           
                           
_
_ products proudly manufactured in the USA _ Specialists in Temperature Measurement
    _
_
©Copyright RdF Corporation. All rights reserved.