Thermocouple values in light gray are outside tolerenced limits__
ASTM E-230

* Indicates maximum temperature for MgO insulated TC diameter 1/8
ASTM E-608

** Indicates maximum temperature for MgO insulated TC diameter 1/4
ASTM E-608

_
Celsius: 1 | 2 | 3     Farenheit: 1 | 2 | 3 | 4 | 5 | 6 | 7   
RdF Platinum RTD & Thermocouple Tables 6.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
°F 100 Ω RTD _ 100 Ω RTD _ T/C _ T/C _ T/C _ T/C _
IEC 751 _ RdF Reference _ Type K _ Type J _ Type T _ Type E _
a=0.00385055 _ a=0.003924008 _ Cr/Al _ Ir/Con _ Cu/Con _ Cr/Con _
resistance, Ω _ resistance, Ω _ millivolts _ millivolts _ millivolts _ millivolts _
_ _ _ _ _ _ _ _ _ _ _ _ _ _
1810   ----   ----   40.798   57.227   ----   75.454  
1820   ----   ----   41.015   57.558   ----   75.872  
1830   ----   ----   41.232   58.888   ----   76.289  
1840   ----   ----   41.449   58.217   ----   ----  
1850   ----   ----   41.665   58.545   ----   ----  
1860   ----   ----   41.881   58.872   ----   ----  
1870   ----   ----   42.096   59.199   ----   ----  
1880   ----   ----   42.311   59.526   ----   ----  
1890   ----   ----   42.526   59.851   ----   ----  
1900   ----   ----   42.741   60.177   ----   ----  
1910   ----   ----   42.955   60.501   ----   ----  
1920   ----   ----   43.169   60.826   ----   ----  
1930   ----   ----   43.382   61.149   ----   ----  
1940   ----   ----   43.595   61.473   ----   ----  
1950   ----   ----   43.808   61.796   ----   ----  
1960   ----   ----   44.020*   62.118   ----   ----  
1970   ----   ----   44.232   62.441   ----   ----  
1980   ----   ----   44.444   62.763   ----   ----  
1990   ----   ----   44.655   63.085   ----   ----  
2000   ----   ----   44.866   63.406   ----   ----  
2010   ----   ----   45.077   63.728   ----   ----  
2020   ----   ----   45.287   64.049   ----   ----  
2030   ----   ----   45.497   64.370   ----   ----  
2040   ----   ----   45.706   64.691   ----   ----  
2050   ----   ----   45.915   65.012   ----   ----  
2060   ----   ----   46.124   65.333   ----   ----  
2070   ----   ----   46.332   65.654   ----   ----  
2080   ----   ----   46.540   65.974   ----   ----  
2090   ----   ----   46.747   66.295   ----   ----  
2100   ----   ----   46.954**   66.615   ----   ----  
2110   ----   ----   47.161   66.935   ----   ----  
2120   ----   ----   47.367   67.255   ----   ----  
2130   ----   ----   47.573   67.575   ----   ----  
2140   ----   ----   47.778   67.895   ----   ----  
2150   ----   ----   47.983   68.214   ----   ----  
2160   ----   ----   48.187   68.534   ----   ----  
2170   ----   ----   48.391   68.853   ----   ----  
2180   ----   ----   48.595   69.171   ----   ----  
2190   ----   ----   48.798   69.490   ----   ----  
2200   ----   ----   49.000   ----   ----   ----  
2210   ----   ----   49.202   ----   ----   ----  
2220   ----   ----   49.404   ----   ----   ----  
2230   ----   ----   49.605   ----   ----   ----  
2240   ----   ----   49.806   ----   ----   ----  
2250   ----   ----   50.006   ----   ----   ----  
2260   ----   ----   50.206   ----   ----   ----  
2270   ----   ----   50.405   ----   ----   ----  
2280   ----   ----   50.604   ----   ----   ----  
2290   ----   ----   50.802   ----   ----   ----  
2300   ----   ----   51.000   ----   ----   ----  
                           
                           