Operating Temperature Range
196°C to 480°C
(320°F to 900°F)
Maximum Operating Temperature:
900°F over tip end length.
Note:
If lead exit temperature
will exceed 260°C (500°F),
please specify on order.
Resistance
See Ordering Specifications Table.
Lead wire resistance to the element
is not included for the 2-wire configuration.
The 3-wire and 4-wire units
allow compensation for
lead wire resistance.
Temperature Coefficients of Resistance:
0.003924 Ω/Ω/°C (Reference)
0.003850 Ω/Ω/°C (IEC/DIN)
Accuracy
±0.25°C @ 0°C (32°F)
±0.3°C @ 0°C (32°F)
on IEC/DIN thin films
|
|
|
|
Stability
Less than 0.05°C shift per year
full span on wire elements
50°C to 300°C (60°F to 500°F)
span on thin films
Self-Heating
75 mW/°F
in water flowing at 3 ft. per sec.
Pressure Rating
3000 PSI
Insulation Resistance
500 Megohms minimum
@100 VDC at room temperature
Time Constant
Less than 2 sec,
in water flowing at 3 ft. per sec.
Standard Leads
22 AWG stranded, nickel plated copper, Teflon® insulated, except 3-wire leads
on type A are 28 AWG. 3 or 4-wire leads over 36" are cabled on type T. Type A 3-wire leads over 36" are not cabled unless designated for operation below 500°F.
Teflon® is a registered trademark
of the DuPont Corporation.
|